I Description About Tamper Detection; I Notification About The Installation Site - Panasonic BM-ET200 Operating Instructions Manual

Iris reader
Hide thumbs Also See for BM-ET200:
Table of Contents

Advertisement

Item
Junction box
Rear cover fixing screw
(Mandatory)
GND cable (Mandatory)
1
*
Only cables without connector covers are usable.
Notes:
• When you use the alarm output and Wiegand terminals, you need optional cables suited for the connectors of external
devices. Use the UL style 1571 or equivalents, AWG 22 - 16 wire.
• When you use the RS-485 terminals, you need optional twisted pair cables (AWG 22 - 16) suited for the connectors of
external devices.
• It is recommended to use shielded twisted pair cables for the open collector output connectors.
G
Cable Preparation
Power cable (with sealing)
25 mm {1 in.} or less
Clamping tool
Earth ground cable (with sealing, supplied)
Note: Use 18 gauge wire or better when connecting to the earth ground.

I Description about Tamper Detection

This iris reader has the tamper detection function to protect the data and setting values stored in the reader. If the iris camera
is left in the tamper detection status for a specified period, the iris data stored in the iris reader will be deleted.
• The tamper detection status can be canceled with Setup Switch 8. Set this switch to ON when the front cover is removed
for servicing. (Refer to p. 21.)
• After servicing, set this switch to OFF, and close the front cover. The iris reader becomes the operation status.
Notes:
• If the front door is not closed after Setup Switch 8 is set to OFF for a specified period, the iris data stored in the iris
reader will be deleted.
• In case the stored data is deleted by the tamper detection, backup of stored data is available. Refer to p. 48 or 58.

I Notification about the Installation Site

This iris reader is limited to indoor use.
Near-infrared light (contained in sunlight, incandescent light and halogen light) is used for iris image capturing by the iris read-
er. If the iris reader is installed in a place which receives this light directly, it may cause invalid iris data enrollment/recognition,
as the iris reader cannot capture iris images properly.
Keep the iris reader away from the following. Otherwise, light may affect on the iris reader.
• Outdoor places
• Direct sunlight or light reflection
Item number/Recommended type
Two gang junction box (4 in. x 4 in.)
_
Use
Necessary when attaching the rear cover to the
wall
Solder both ends of the cable with M3 screw
clamp terminals. Use the supplied earth ground
cable to connect the earth ground.