Table 9-3 Event Log Entries Unique to the Equipment (2/3)
Event
No.
Source
ID
14
524
HFWRAS_SYS
15
525 HFWRAS_SYS
16
539 HFWRAS_SYS
17
540 HFWRAS_SYS
18
541 HFWRAS_SYS
19
769 HFWRAS_APP
20
771 HFWRAS_APP
21
800 HFWRAS_SYS
22
900 HFWRAS_SYS
23
2001 HFWRAS_SYS
24
2002 HFWRAS_SYS
Type
Description
Information
In the current settings,
memory dump file won't
be saved. %1
Information
In the DIMM %1, error
correctings have occurred
with high frequency.
Error
The "%1" was finished.
Information
In the DIMM %1, detected
the number of single bit
error from the OS boot
is %2 times(difference
between the last time:%3).
Warning
DIMM %1 failure might
occur.
Error
An error occurred in %1.
errorcode = %2.
Error
Because a wrong value is
set up in registry value
"%1", default value %2 is
set up.
%1
Information
Detailed code = %2.
Information
Power shutdown factor
code is %1.
Error
The drive on the drive
bay%1 is OFFLINE
because of failure.
Information
RAID status is OPTIMAL. No handling
9-23
9. TROUBLE SHOOTING
Action
See "8.2.1" and take action, or see
"8.2.2" and change the setting by
manual operation.
The DIMM may be out of order. Contact
your system administrator or
maintenance personnel.
Hardware monitoring of the RAS
software has been terminated. If
restarting the equipment does not
resolve the error, contact the system
administrator or maintenance personnel.
No handling.
The DIMM may be out of order. Contact
your system administrator or
maintenance personnel.
An error was generated by the RAS
software while the software was
running. If restarting the equipment does
not resolve the error, contact the system
administrator or maintenance personnel.
If restarting the equipment does not
resolve the error, contact the system
administrator or maintenance personnel.
A STOP error has occurred. Check the
error and contact your system
administrator or maintenance personnel.
A power shutdown occurred. Contact
your system administrator or
maintenance personnel.
Read the description of abnormal
temperature in "10.4.2" and take action
accordingly.