< NOTE >
・ If you mount the replacement drive before "Not mounted" is shown, it might not
be recognized. Make sure that you wait until "Not mounted" is displayed.
6. Mount the replacement drive on the computer.
(See "6.3.6 Installing and removing an HDD/SSD".)
The HDD/SSD status lamp blinks after a while and RAID1 rebuilding starts.
< NOTE >
・ If rebuilding does not start after about three minutes, the drive or equipment
might have failed or a drive has been used as a RAID1 array for other
equipment might have been installed. For details, see "10.4.3 When a Problem
Occurs During Recovery".
・After the drive has been mounted on the equipment, the hardware status display
window displays the drive bay status, as shown in the following figures until
rebuilding is completed.
Note that "Offline" might not be displayed immediately after the drive is mounted.
Immediately after the drive is mounted
During rebuilding
10-11
10. RAID1