Chapter 2 Useful Features
4.6.2 Manual Rebuild
1.
Replace a physical device, and then restart the server.
2.
Run LSI Software RAID Configuration Utility.
3.
From the TOP menu, select Drive Management, and then Select Drive Operations.
The following screen appears.
4.
Confirm that the target physical device is displayed for Select Drive.
By default, Rebuild starts automatically after you replace the physical device.
Tips
Important
In the UEFI Mode, Rebuild on the LSI Software RAID Configuration Utility takes long
time. Run Rebuild from the Universal RAID Utility on the OS.
If you need to run Rebuild on the LSI Software RAID Configuration Utility, follow the
procedure below.
Replace a physical device
Run LSI Software RAID Configuration Utility
Perform the Rebuild process
Exit LSI Software RAID Configuration Utility
Express5800/B120f-h Maintenance Guide
4. RAID System Configuration
119