NEC Express5800 Series Maintenance Manual page 163

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
Mezzanine Slot 1 - PCIE Link
B341
Failure
B342
Mezzanine Slot 2 - PCIE Link
Failure
B343
Mezzanine Slot 3 - PCIE Link
Failure
B344
Mezzanine Slot 4 - PCIE Link
Failure
B348
PCI Slot - PCIE Link Failure
B34A
I/O Blade PCI Slot - PCIE Link
Failure
B371
Mezzanine Slot 1 - PCIE Link
Width Error
B372
Mezzanine Slot 2 - PCIE Link
Width Error
B373
Mezzanine Slot 3 - PCIE Link
Width Error
B374
Mezzanine Slot 4 - PCIE Link
Width Error
B378
PCI Slot - PCIE Link Failure
B37A
I/O Blade PCI Slot - PCIE Link
Width Error
B3A0
CLP Command Failure
B3A1
EM Failure Pause
C010
The error occurred during
temperature sensor reading
C011
System Temperature out of the
range.
C020
The error occurred during
voltage sensor reading.
C021
System Voltage out of the
range.
C040
SROM data read error
C041
SROM data checksum bad
C061
1st SMBus device Error
detected.
C062
2nd SMBus device Error
detected.
C063
3rd SMBus device Error
detected.
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C101
BMC Memory Test Failed..
C102
BMC Firmware Code Area CRC
check
Failed.
C103
BMC core hardware failure.
C104
BMC IBF or OBF check failed.
C105
BMC SEL area full.
Cause
Connection failure of PCIe bus was
detected on Mezzanine Slot 1.
Connection failure of PCIe bus was
detected on Mezzanine Slot 2.
Connection failure of PCIe bus was
detected on Mezzanine Slot 3.
Connection failure of PCIe bus was
detected on Mezzanine Slot 4.
Connection failure of PCIe bus was
detected on PCI Slot.
Connection failure of PCIe bus was
detected on I/O Blade PCI Slot.
Link Width error was detected on
Mezzanine Slot 1.
Link Width error was detected on
Mezzanine Slot 2.
Link Width error was detected on
Mezzanine Slot 3.
Link Width error was detected on
Mezzanine Slot 4.
Connection failure of PCIe bus was
detected on PCIe
Link Width error was detected on I/O
Blade PCI Slot.
CLP Command failed to execute on
BIOS.
CLP Command failed to set on EM.
An error occurred while reading the
temperature sensor.
A temperature abnormality was
detected.
An error occurred while reading the
voltage sensor.
A system voltage abnormality was
detected.
SROM data reading error
SROM checksum error
An error occurred in the 1st SM Bus.
An error occurred in the 2nd SM
Bus.
An error occurred in the 3rd SM
Bus.
An error occurred in the 4th SM Bus.
An error occurred in the 5th SM Bus. Contact your sales representative.
An error occurred in the 6th SM Bus.
An error occurred in the 7th SM Bus.
An error occurred in the 8th SM Bus.
BMC device (chip) error was
detected
Accessing the BMC address failed.
There is not enough capacity to
write the system event log.
Express5800/B120f-h Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Contact your sales representative.
It is possible that a fan has failed or is
clogged. Contact your sales
representative.
Contact your sales representative.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Run the Offline Tools and delete the event
logs.
163

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120f-h exp437a