NEC Express5800 Series Maintenance Manual page 164

Hide thumbs Also See for Express5800 Series:
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
BMC update firmware corrupted. An error was detected while
C10C
C10D
Internal Use Area of BMC FRU
corrupted.
C10E
BMC SDR Repository empty.
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
C111
BMC SDR Repository failure.
C112
BMC SEL device failure.
C113
BMC RAM test error.
C114
BMC Fatal hardware error.
C115
Management controller
not responding
C116
Private I2C bus not
responding.
C117
BMC internal exception
C118
BMC A/D timeout error.
C119
SDR repository corrupt.
C11A
SEL corrupt.
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition is
invalid.
C11D
BMC is in Forced Boot Mode.
C11E
Communication with BMC was
failed in previous boot
C11F
Backup Data of BMC Mezzanine
card has corrupted.
164
Cause
updating BMC firmware.
An illegality was detected in FRU
that stores the chassis information.
An error was detected on BMC
SDR.
Satellite Management Controller
(SMC) failure was detected.
Failure of the SROM for storing
chassis information was detected.
Failure of the SROM for storing
sensor data record data was
detected.
BMC device (chip) failure was
detected.
BMC RAM error was detected.
BMC error was detected.
Management controller does not
respond.
Private I2C bus does not respond.
BMC internal error was detected.
BMC A/D timeout error was
detected.
BMC error or illegal SDR data was
detected.
BMC error or illegal system event
log data was detected.
BMC Mezzanine card is not
mounted.
BMC Mezzanine partition is invalid.
Detected that BMC is in Forced Boot
Mode.
Communication with BMC was
failed in previous boot
Inconsistency was found on BMC
mezzanine card.
Express5800/B120f-h Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Turn off the power, wait for at least 30
seconds, and restart the server.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Contact your sales representative.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
Contact your sales representative.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/b120f-h exp437a

Table of Contents