Error Message
A014
Memory Error detected in
CPU2_DIMM8
A015
Memory Error detected in
CPU2_DIMM9
A420
Online Spare Memory was not
ready.
A421
Mirroring Memory was not
ready.
A423
Lockstep was not ready.
A428
Cluster On Die was not
ready.
A429
DIMM population is
insufficient for Cluster On
Die.
A800
Memory not detected
A804
Latest memory module is
corrupted.
AE01
CPU1_DIMM1 has been disabled. A memory error was detected.
AE02
CPU1_DIMM2 has been disabled. A memory error was detected.
AE03
CPU1_DIMM3 has been disabled. A memory error was detected.
AE04
CPU1_DIMM4 has been disabled. A memory error was detected.
AE05
CPU1_DIMM5 has been disabled. A memory error was detected.
AE06
CPU1_DIMM6 has been disabled. A memory error was detected.
AE06
CPU1_DIMM6 has been disabled. A memory error was detected.
AE07
CPU1_DIMM7 has been disabled. A memory error was detected.
AE08
CPU1_DIMM8 has been disabled. A memory error was detected.
AE09
CPU1_DIMM9 has been disabled. A memory error was detected.
Cause
An error was detected on
CPU2_DIMM8.
An error was detected on
CPU2_DIMM9.
Failed to enable the Sparing feature
by the current memory
configuration.
Failed to enable the Mirroring
feature by the current memory
configuration.
Failed to enable the LockStep
feature by the current memory
configuration.
Cluster On Die feature is
disabled in this hardware
configuration.
Cluster On Die feature cannot work
with this memory configuration.
No available memory is installed.
The BIOS flash memory was failed.
CPU1_DIMM1 has been disabled.
CPU1_DIMM2 has been disabled.
CPU1_DIMM3 has been disabled.
CPU1_DIMM4 has been disabled.
CPU1_DIMM5 has been disabled.
CPU1_DIMM6 has been disabled.
CPU1_DIMM6 has been disabled.
CPU1_DIMM7 has been disabled.
CPU1_DIMM8 has been disabled.
CPU1_DIMM9 has been disabled.
Express5800/B120f-h Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Contact your sales representative.
Start SETUP, and confirm the settings of
Memory RAS Mode. When Memory
Sparing, Memory Mirroring, or Memory
LockStep feature is enabled, POST
detects this error if DIMMs are degraded.
Start SETUP, and specify Yes for
Memory Retest, then execute Save
Changes and Exit.
Replace the processor with the one that
supports this feature. Or, run SETUP and
select Disabled for the Cluster On Die.
Check if memory configuration is correct.
Check if DIMMs are properly installed..
Contact your sales representative.