Messages displayed on a lower LCD line
BMC Message on Lower LCD Line
ProcessorX Voltage Lower Non-Critical
(X: 1 or 2)
ProcessorX Voltage Upper Non-Critical
(X: 1 or 2)
ProcessorX Voltage Lower Critical (X: 1
or 2)
ProcessorX Voltage Upper Critical (X: 1
or 2)
BaseBoard Voltage Lower Non-Critical
BaseBoard Voltage Upper Non-Critical
BaseBoard Voltage Lower Critical
BaseBoard Voltage Upper Critical
VBAT Lower Non-Critical
VBAT Upper Non-Critical
VBAT Lower Critical
VBAT Upper Critical
Baseboard Temperature1 Lower
Non-Critical
Baseboard Temperature1 Upper
Non-Critical
Baseboard Temperature1 Lower Critical
Baseboard Temperature1 Upper Critical
CPUX_DIMM Area Temperature
Upper Non-Critical (X: 1 or 2)
CPUX_DIMM Area Temperature
Upper Critical (X: 1 or 2)
ProcessorX Thermal Control Upper
Non-Critical (X: 1 or 2)
ProcessorX Thermal Control Upper
Critical (X: 1 or 2)
ProcessorX Thermal Trip (X: 1 or 2)
Insufficient Cooling Error (Not Power
ON)
DUMP Request !
Processor Missing
CPU1_DIMMX Uncorrectable Error
(X: number)
168
Cause
A voltage abnormality was
detected.
A temperature abnormality was
detected.
A temperature abnormality was
detected.
The power was forcibly turned off
due to a CPU temperature
abnormality.
The CPU blade failed to power on
due to insufficient cooling power.
In the Blade Enclosure, the
number of fans installed is
insufficient or the installed fan is
faulty.
DUMP switch is pressed.
No CPU is installed in CPU #1
socket.
An uncorrectable error occurred
on DIMM for CPU #1.
X: Failed DIMM number (1-origin)
Express5800/B120f-h Maintenance Guide
1. Error Message of POST and Virtual LCD
Solution
Contact your sales representative.
Check if fans in Blade Enclosure work
normally. Refer to the User's Guide of
the Blade Enclosure to make sure that
the sufficient number of fans is installed,
and CPU blades and fan units are
installed in correct locations. Check
installation status of heat sink of the
CPU blade. Check if ambient
temperature of installation location
satisfies the operation guarantee
condition.
Wait until completion of memory dump
process.
Check installation status of the CPU
blade.
Contact your sales representative.