13.9 Faults

13.10 VdS operation

Bus Motion Detector
Wait for the display on the keypad.
Delete
OK
The error messages of the bus motion detector are displayed via the LCD
keypad with the error and signal LEDs as well as on the display.
Example of a fault indicator:
XIB-M73 Gestört
AM-cal
PIR-Alm
Hereby, the respective motion detector is displayed with its circuit and
associated fault. More information such as the time can be viewed using the
arrow keys of the keypad.
Overview of the faults:
Displayed
Description
text
PIR Alm
Fault of passive infra red sensors
UW-Alm
Microwave sensor fault
PIR-AM
Passive infra red anti-masking triggered
UW-AM
Microwave anti-masking triggered
AM-cal
Calibration fault of the anti-masking monitoring
AM-Cct
Calibration error of the microwave anti-masking
monitoring (only EIM/X detector)
PIR-Alm
Error cause of the passive infrared sensors (is only
displayed in combination with other faults)
UW-Alm
Error cause of the microwave sensors (is only displayed
in combination with other faults)
For VdS compliant operation of the bus motion detector the following
parameter settings must be set in addition to the factory settings:
Function
Cct
Impulses
UW TAG
Anti-mask
Red. range
LED red
LED yellow
LED green
AM Sens.
Fault
Undervoltage
Anti stealth
Log
The bold settings are suggested for VdS operation.
Type designation
IR/XB
IR/XC
nn
nn
2
2
*
*
*
on
off
off
off
off
*
off
*
*
*
on
on
on
on
on
*
*
on
on
EIM/XB
EIM/XC
nn
nn
1
1
off
off
on
on
off
off
off
off
off
off
off
off
on
on
on
on
on
on
on
on
on
on