Description Of The Inputs And Outputs - ABB L240 Series Installation, Commissioning & Operation

Security technology knx-intrusion alarm system
Hide thumbs Also See for L240 Series:
Table of Contents

Advertisement

3.4
Description of the inputs
and outputs
Terminal
Designation
CN17
V+
+ 12 V
V-
0 V
CN18
V+
+ 12 V
V-
0 V
CN2
1
Cct 1 (+)
C
Common (-)
2
Cct 2 (+)
CN25
3
Cct 3 (+)
C
Common (-)
4
Cct 4 (+)
CN3
5
Cct 5 (+)
C
Common (-)
6
Cct 6 (+)
CN27
7
Cct 7 (+)
C
Common (-)
8
Cct 8 (+)
CN4
9
Cct 9 (+)
C
Common (-)
10
Cct 10 (+)
CN6
11
Intrusion
12
Personal attack
13
External unset:
14
Fault
CN26
15
Setting (arming)
acknowledgement
16
Ready to set
17
Internal alarm
18
Unset
Installation Instructions
Terminal designation in a clockwise direction commencing at the top left
(P) = programmable
Function (delivery state)
+ 12 V DC buffered voltage for
external devices
+ 12 V DC buffered voltage for
external devices
Intrusion cct
(switched off as with int. set,
e.g. for motion detectors)
Common 0V for cct 1 + 2
Intrusion cct
(switched off as with int. set,
e.g. for motion detectors)
Intrusion cct
(switched off as with int. set,
e.g. for motion detectors)
Common 0V for cct 3 + 4
Intrusion cct
Intrusion cct
Common 0V for cct 5 + 6
Intrusion cct
Door lock circuit
Common 0V for cct 7 + 8
Personal attack cct
Tampering circuit
Common 0V for cct 9 + 10
External set cct
Transistor outputs switch active
0V, (via resistor 820 , max. 15
mA)
Transistor outputs switch active
0V, (via resistor 820 , max. 15
mA)
Remark:
Fuse:
FS1 0.8 A quick-blow
Fuse:
FS2 0.8 A fast-blow
(P) Unset:
display only
internal set:
display only
external set:
External alarm
(P) Unset:
display only
internal set:
display only
external set:
External alarm
(P) Unset:
display only
internal set:
display only
external set:
External alarm
(P) Unset:
display only
internal set:
Internal alarm
external set:
External alarm
(P) Unset:
display only
internal set:
Internal alarm
external set:
External alarm
(P) Unset:
display only
internal set:
Internal alarm
external set:
External alarm
(P) Leads to setting (arming) prevention on an
interrupt
(P) External alarm and personal attack output
(P) Unset:
Buzzer and internal alarm
internal set:
Buzzer and internal alarm
external set:
External alarm
(P) For connection of external switching devices
Switches 0V with intrusion alarm from all
areas for the set alarm time
Switches 0V with personal attack from all
areas for the set alarm time
Switches 0V at external unset system, high
impedance if externally set.
Switches 0V, if no malfunction from power
supply, common fail or processor present
Switches 0V for approx. 3 seconds if system
has been externally set (armed)
Switches 0V if system ready to set externally
Switches 0V on internal alarm
Switches 0V if system unset.