ABB L240 Series Installation, Commissioning & Operation page 17

Security technology knx-intrusion alarm system
Hide thumbs Also See for L240 Series:
Table of Contents

Advertisement

Terminal
Designation
CN14
19
Relay 1 (NO)
20
Relay 1 (NC)
21
Relay 1 (common)
CN12
22
Relay 2 (NO)
23
Relay 2 (NC)
24
Relay 2 (common)
CN9
25
Internal buzzer (+)
26
Internal buzzer (-)
CN16
27
free
28
Strobe light (+)
29
Strobe light (-)
CN19
30
Siren 1 (-)
31
Siren 2 (-)
32*
Siren 1 & 2 (+)
CN5
33
Comm fail fault
34
Comm fault alarm
(Negative
acknowledgement)
CN24
35
Panel tamper (+)
36
Common (-)
CN13
+,-,A,B External Bus (XIB)
CN11
+,-,A,B Internal bus for
keypad 0 (service
keypad)
VR 1
Battery charging
voltage
VR 2
Systems voltage
LK7
Temperature
sensor
CN7
+, -
Battery 2
CN15
+, -
Battery 1
AC
IN, IN
approx. 20 V AC
GND
from transformer
CN8
42
Relay (NC)
43
Relay (NO)
44
Relay 1 (common)
- On VdS systems, siren 2 must be supplied by terminal V+ (CN17 or 18).
-
The transistor outputs 1-8 are assigned in the delivery state with the functions of area 1 described in the table.
Note: Output 1 "Intrusion" switches with an intrusion alarm from all areas. Output 2 "Personal attack" switches
with an intrusion alarm from all areas. It can be reprogrammed (output address 0).
Installation Instructions
Function (delivery state)
External set
Walk test
(Active 0V)
(Active 0V)
(Active 0V)
Connection of the fault relay of
the comm fault. Normally
connected with jumper to 0 V.
Connection of the alarm relay of
the comm fault. Only if the panel
is programmed for a silent alarm.
Normally connected with jumper
to 0 V.
Panel tamper of the central
enclosure
For connection of keypads (1-7)
and bus modules
Connection of the engineer
keypad (address 0)
Factory setting 13.8 V at 20°C.
Factory setting 14.0 V.
For temperature dependent
charging voltage of the battery
Permanent alarm relay
Remark:
Relay switches with external set
(P)
(P) Relay switches, if the walk test function on the
keypad has been activated
Switches with system interrupt, tamper alarm
(unset) and after unset, in order to draw
attention to a triggered alarm.
Switches with external alarm until reset. Fuse
FS3 800 mA quick-blow
Switches with external alarm for the set alarm
time (180 seconds)
Fuse FS3 800 mA quick-blow
With an open contact on the comm (fault) of
the setting prevention
Generates a local alarm, if the comm fault
could not issue a silent alarm.
Unset:
Buzzer and internal alarm
internal set:
Buzzer and internal alarm
external set:
External alarm
Fuse FS3 800 mA quick-blow
(not keypad 0)
The temperature sensor is connected as near
as possible to the batters with a cable tie.
From the transformer and mains connection
with integrated fuse, 400 mA slow-blow.
Switches with local alarm until reset.
17