Menu 11 "Log Eng On; Menu 12 "Tamp.reset - ABB L240 Series Installation, Commissioning & Operation

Security technology knx-intrusion alarm system
Hide thumbs Also See for L240 Series:
Table of Contents

Advertisement

6.3.11 Menu 11 "Log Eng On"

User-PIN
01 = Int Set
02 = Cct Off
03 = Disp Cct Off
04 = Change PIN
05 = Disp CctFault
06 = Test
07 = Alarm Counter
08 = Log
09 = Ext Set *
10 = Time/Date *
11 = Input Eng.PIN
12 = Tamp.Reset *
14 = Delete **
15 = Cancel Print

6.3.12 Menu 12 "Tamp.Reset"

User-PIN
01 = Int Set
02 = Cct Off
03 = Disp Cct Off
04 = Change PIN
05 = Disp CctFault
06 = Test
07 = Alarm Counter
08 = Log
09 = Ext Set *
10 = Time/Date *
11 = Input Eng.PIN
12 = Tamp.Reset *
14 = Delete **
15 = Cancel Print
Operation of the L240
Menu item 11 "Log Eng On" To gain use of access level 2 it is necessary
to enter the 6-digit Engineer PIN and confirm it with the
access is stored along with the user no. 9 in the event log. In the default
delivery state, the Engineer PIN is set to "000000". Only one Engineer PIN is
available for each panel.
Log Eng On
Input PIN:
Menu item 12 "Tamp.Reset" VdS: With a Tamper Reset, stored tamper
alarms (e.g. tamper circuit groups, panel tamper contacts, setting inputs or
signalling device cables) and battery faults are reset. Currently active
interrupts on tamper lines cannot be deleted. After enabling this function, the
tampering alarms and battery faults can also be reset by the user. This
function is factory enabled for one user to allow a reset of tamper alarms
directly in access level 0 (without PIN entry requirement) that were triggered
during commissioning by the Engineer/Installer. After commissioning this
function should be inhibited for the user and is only accessible after entering
the Engineer code. Only tamper alarms triggered in the same area where the
keypad is located can be deleted.
Reset of alarms: After an alarm is triggered (external alarm), it is described
in detail on the LCD display after unsetting and entry of the user PIN. If
several alarms are present, these are shown consecutively, or you can page
><
through them with the
Reset" prompt appears. The alarm is deleted by pressing the
buttons. After pressing the
!
button. Each
X
button, the "4-
!
button.
34

Advertisement

Table of Contents
loading

Table of Contents