12.7.3 Access

12.7.4 Personal attack

L240/BS
Access can occur in the unset state:
1.
With keypad code
Enter a valid 6-digit key code.
2.
With chip key
Insert and remove a valid chip key once.
With a strike plate and door cylinder the coupling system is activated for 6
seconds. The door can be unlocked and opened with the exterior handle.
The entry of the keypad code "Personal attack" triggers a "Personal attack
alarm" independently of the state of the Intrusion Alarm Panel (transistor
output "PA" of the L240).
 In the unset state, the strike plate will also enable access.
 In the unset state, "Personal attack" is triggered and "Access" is allowed.
 In the set state with VdS class A, after entry of the personal attack code a
"Personal attack" is triggered, the area is switched to unset and "Access"
allowed.
 In the set state with VdS class B, after entry of the personal attack code a
"Personal attack" is triggered, but the area remains set. After insertion of
a chip key with unset authorization, the area is switched to unset and
"Access" allowed.
 In the set state with VdS class C, the keypad code "Personal attack" is
the first condition for unset switching. After insertion of a valid chip key
(second condition) the unset switching occurs, a "Personal attack" is
triggered and access for opening the door is also enabled on the strike
plate.
 The authorization "PA" can only be defined for a keypad code.