Toshiba e-studio200l Service Handbook page 176

Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

Classifi-
Code
cation
1394
Paper
Feeding retry counter
feeding
(bypass feed)
1395
Paper
Feeding retry counter
feeding
(LCF)
1396
Paper
Feeding retry counter
feeding
upper limit value
(Upper drawer)
1397
Paper
Feeding retry counter
feeding
upper limit value
(Lower drawer)
1398
Paper
Feeding retry counter
feeding
upper limit value
(PFP upper drawer)
1399
Paper
Feeding retry counter
feeding
upper limit value
(PFP lower drawer)
1400
Paper
Feeding retry counter
feeding
upper limit value
(Bypass feed)
1401
Paper
Feeding retry counter
feeding
upper limit value
(LCF)
1410
Counter
Counter for period of toner
cartridge rotation time
1411
Counter
Counter for envelope
1422
Data
HDD data overwriting type
overwrite
setting
kit
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ERROR CODE AND SELF-DIAGNOSTIC MODE
Setting mode (08) <e-STUDIO200L/230/230L/280>
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2 - 140
05/05
Default
<Accept-
RAM
able
value>
0
M
Counts the number of
<8 digits>
times of the feeding
retry from the bypass
tray.
0
M
Counts the number of
<8 digits>
times of the feeding
retry from the LCF.
0
M
When the number of
<8 digits>
feeding retry (08-1390
to 08-1395) exceeds
the setting value, the
0
M
feeding retry will not be
<8 digits>
performed subse-
quently. In case "0" is
0
M
set as a setting value,
<8 digits>
however, the feeding
retry continues regard-
0
M
less of the counter set-
<8 digits>
ting value.
0
M
<8 digits>
0
M
<8 digits>
0
M
Counts up the period of
<8 digits>
rotation time of the
toner cartridge.
0
M
Counts up when the
<8 digits>
registration sensor is
ON.
When the counter value
of the fuser roller is
reset, this counter is
reset in sync at the PM
support mode.
3
SYS
HDD data is cleared by
<0-4>
overwriting the type of
value set in this code.
(This setting is enabled
only when the GP-1050
is installed.)
0: "00" overwriting only
1: "FF" overwriting
only
2: Random number
overwriting only
3: "00" + "FF" + ran-
dom number over-
writing (validation
ON)
4: "00" + "FF" + ran-
dom number over-
writing (validation
OFF)
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
Proce-
Contents
dure
1
1
1
1
1
1
1
1
1
1
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents