<Procedure>
Perform 08-477 and check the value.
When the value is 0.
[0] [5] [Power ON]  [1] ([3](05-445, 498) for duplexing)  [FAX]
A:
05-401 (Lower drawer, A3/LD)
B:
05-411 (Lower drawer, A3/LD)
C:
05-421 (Lower drawer, A3/LD)
D:
05-441 (Lower drawer, A3/LD), 440 (Upper drawer, A4/LT), 444 (PFP, A4/LT),
443 (LCF, A4/LT), 442 (Bypass feed, A4/LT), 445 (Duplexing, A3/LD)
E:
05-498-0 (Lower drawer, A3/LD),
498-1 (Upper drawer, A4/LT)
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
A
6
B, E
Fig. 3-8 Grid pattern
 200±0.5 mm (0.125 mm/step)
 52±0.5 mm (0.05 mm/step)
 Key in the same value for 05-410.
 200±0.5 mm (0.125 mm/step)
 52±0.5 mm(0.4 mm/step)
 52±0.5 mm (0.05 mm/step)
3 - 11