Toshiba e-studio200l Service Handbook page 368

Hide thumbs Also See for e-studio200l:
Table of Contents

Advertisement

[B]
Adjustment of the magnification ratio of the lens
Notes:
Perform this adjustment only when the lens unit is taken off or replaced.
Make sure that the primary scanning reproduction ratio (printer section) is correct before this
adjustment.
(1)
Place a ruler on the original glass (in the primary scanning direction) and make a copy on A4/LT-
sized paper at 100% reproduction ratio.
(2)
Compare the copied ruler with the actual
ruler.
(3)
If each mark on the rulers differs, perform the adjustment with the following procedures.
<Procedure>
(1)
Take off the original glass and lens cover.
(2)
Loosen 2 screws fixing the lens unit.
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
ADJUSTMENT
Feeding Direction
Copied ruler
Screw
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
3 - 48
Actual ruler
Fig. 3-37
Lens unit
Fig. 3-38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents