[CC90] Upper stack tray lift motor abnormality
MJ-1022
Is the wiring between the finisher controller PC board and upper stack tray lift motor (M5)
correct?
NO 
YES
Are the front and rear sides of the upper stack tray leveled?
NO 
YES
Is the upper stack tray lift motor clock sensor (S19) working properly?
NO 
YES
Is the stack tray paper height sensor (S10) working properly?
NO 
YES
Are the upper stack tray upper limit sensor (S25), upper stack tray full sensor (S22) and
stack processing safety switch (S26) working properly?
NO 
YES
Does the voltage between the pins J14-1 pin and -2 pin on the finisher controller PC board
become 24 V when the upper stack tray lift motor starts rotating?
NO 
YES
Check the wiring between the upper stack tray lift motor and finisher controller PC board. If
there is no problem, replace the upper stack tray lift motor.
© 2004 - 2010 TOSHIBA TEC CORPORATION All rights reserved
Correct the wiring.
Level them.
Replace the sensor.
Replace the sensor.
Replace the sensor or sensor controller PC board.
Replace the finisher controller PC board.