[CCA0] Lower stack tray lift motor abnormality
MJ-1022
Is the wiring between the finisher controller PC board and lower stack tray lift motor (M7)
correct?
NO 
YES
Are the front and rear sides of the lower stack tray leveled?
NO 
YES
Is the lower stack tray lift motor clock sensor (S9) working properly?
NO 
YES
Is the stack tray paper height sensor (S10) working properly?
NO 
YES
Are the lower stack tray upper limit sensor (S13) and lower stack tray full sensor (S23) work-
ing properly?
NO 
YES
Does the voltage between the pins J3-1 pin and -2 pin on the finisher controller PC board
become 24 V when the lower stack tray lift motor starts rotating?
NO 
YES
Check the wiring between the upper stack tray lift motor and finisher controller PC board. If
there is no problem, replace the motor.
e-STUDIO200L/202L/203L/230/230L/232/233/280/282/283
TROUBLESHOOTING
Correct the wiring.
Level them.
Replace the sensor.
Replace the sensor.
Replace the sensor or sensor controller PC board
Replace the finisher controller PC board.