Examples
4.1
Programmable contour accuracy
Extract from part program
N10 X0 Y0 G0
N20 CPRECON
N30 F10000 G1 G64 X100
N40 G3 Y20 J10
N50 G1 X0
N100 CPRECOF
N110 G0 ...
Special functions: Contour Tunnel Monitoring (K6)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0
; Enabling of contour accuracy defined by MD
; Machine contour at 10 m/min in continuous-path mode
; Automatic limitation of feed in circle block
; Feedrate again 10m/min
; Disabling of programmed contour accuracy
4