Siemens sinumerik 840D sl Function Manual page 473

Hide thumbs Also See for sinumerik 840D sl:
Table of Contents

Advertisement

Detailed description
2.1 Loadable compile cycles 840D/840D sl
2.1.3
Loading a compile cycle from an external computer with WinSCP3
Requirement
To transfer the compile cycle to the control, the following requirements must be met:
• The external computer (programming device/PC) which the compile cycle is loaded onto
• The program "WinSCP3" is installed on the external computer (programming device/PC).
• The host name or the IP address of the PCU is known.
• The user name and the password to log onto the PCU are known.
Execution
Perform the following operation to load a compile cycle from an external computer into the
NCK:
1. Start the "WinSCP3" program on the external computer (programming device/PC)
2. Establish a connection to the PCU by selecting an appropriate profile or by entering the
3. Copy the compile cycle from the external computer (programming device/PC) into the
4. Trigger an NCK reset to load the compile cycle into the NCK system software.
2.1.4
Interface version compatibility
The compile cycle and the NCK system software communicate via a SINUMERIK-specific
interface. The interface version used by the loaded compile cycle must be compatible with
the interface version of the NCK system software.
12
is linked to the PCU via a network (TCP/IP).
host name or IP address, the user name and the password.
following directory on the PCU: /card/oem/sinumerik/data/cc
Capital letters are not permitted in the file name of the compile cycle in the PCU directory.
Special functions: Installation and Activation of Loadable Compile Cycles (TE01)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0