Detailed description
2.5 Generic coupling
Denominator of the coupling factor
Syntax:
Identifiers:
Functionality:
Value:
Example:
CPLDEN[X2,X1]=2
Programming: Curve tables
When programming a table number, a previously activated non-linear coupling relationship
(coupling factor) is deactivated.
The leading axis specific coupling component for the leading value of the leading axis is
calculated using the specified curve table.
Syntax:
Identifiers:
Functionality:
Value:
96
CPLDEN[FAx,LAx]= <value>
Coupling Lead Denominator
Defines the denominator of the coupling factor for the coupling rule of
the following axis/spindle FAx to the leading axis/spindle LAx.
Type: REAL
Range of
-2
31
values:
Default value:
+1.0
; The denominator of the coupling factor of the coupling of the
following axis X2 to the leading axis X1 must be 2.
CPLCTID[FAx,LAx]= <value>
Coupling Lead Curve Table Id
Specifies the number of the curve table to be used to calculate how the
leading axis/spindle must act on the following axis/spindle.
Type: INT
Range of
-2
15
values:
to +2
31
to +2
15
Special functions: Axis Couplings and ESR (M3)