Detailed description
2.7 Function -specific display data
3. Activate the SGUD.DEF file.
The GUD variables for clearance control are now displayed under:
Operating area switchover > Parameters > User data > Channel spec. user data
SINUMERIK NCK
The new GUD variables, which are already being displayed, will only be detected by the
clearance control function and supplied with up-to-date values following an NCK POWER
ON RESET.
Note
Once the GUD variables have been created, an NCK POWER ON RESET must be carried
out in order for the clearance control function to update the GUD variables.
2.7.2
OPI variable
The "clearance control" technological function provides the following channel-specific OPI
variables as display data for the HMI application:
• SINUMERIK HMI Advanced
Table 2-2
OPI variable
CLC[0]
CLC[1]
CLC[2]
CLC[3]
CLC[4]
CLC[5]
CLC[6]
CLC[7]
CLC[8]
Once the technological function has been started up successfully, the OPI variable is not
available automatically.
44
Channel-specific OPI variable
Description
Current position offset
Absolute minimum of position offset mm
Absolute maximum of position
offset
Current sensor input voltage
Absolute minimum of sensor input
voltage
Absolute maximum of sensor input
voltage
1st component of the standardized
tool orientation vector
2nd component of the standardized
tool orientation vector
3rd component of the standardized
tool orientation vector
Unit
Access
mm
read only
read/write
mm
read/write
V
read only
V
read/write
V
read/write
-
read only
-
read only
-
read only