Siemens sinumerik 840D sl Function Manual page 532

Hide thumbs Also See for sinumerik 840D sl:
Table of Contents

Advertisement

Note
Before the clearance control function is activated for the first time, check that the entire
working range enabled for clearance control is collision-free:
• MD62505 $MC_CLC_SENSOR_LOWER_LIMIT (lower clearance control motion limit)
• MD62506 $MC_CLC_SENSOR_UPPER_LIMIT (upper clearance control motion limit)
An incorrect control direction can be corrected using one of the following methods:
• Reversing the polarity of the analog input
• Changing the sign of all values in the following machine data:
Sensor signal
The quality of the analog input signal can be checked using the function-specific display data
described in the "Function-Specific Display Data" section.
Function-specific alarm texts
Function-specific alarm texts must first be integrated into the appropriate HMI data
management before they can be displayed. A description of how to do this appears in the
"Creating Alarm Texts" section.
Completion
A data backup is recommended once the start-up procedure has been completed.
References:
/IAD/ Commissioning Manual SINUMERIK 840D/611D, data backup
/HBi/ SINUMERIK 840Di Manual, user data backup/ series startup
Note
A data backup is recommended once the start-up procedure has been completed.
Special functions: Clearance Control (TE1)
Function Manual, 11/2006, 6FC5397-2BP10-2BA0
– MD62511 $MC_CLC_SENSOR_VELO_TABLE_1 (coordinate velocity of interpolation
points sensor characteristic 1)
– MD62513 $MC_CLC_SENSOR_VELO_TABLE_2 (coordinate velocity of interpolation
points sensor characteristic 2)
Detailed description
2.5 Startup
27

Hide quick links:

Advertisement

Table of Contents
loading