10.6 Device Range that Can Be Set
The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may not
be monitored.
■1. Setting item
Item
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of word device.
Device
Memory No.
Information
Displays the device type and setting range which are selected in [Device].
Set the monitor target of the set device.
All
Network
Station No.
*1
*2
10 - 20
10.6 Device Range that Can Be Set
*1
Set the memory number (None, 0 to 7) of the device to be monitored.
Select this item when writing data to all the indicating controllers connected.
During monitoring, the indicating controller which is set for [Host Address] of the communication detail setting is monitored.
(When writing the data in numerical input, the data is written to all connected indicating controllers during input, and the
indicating controller that is set for [Host Address] is monitored during other than input (displaying).)
Select this item when monitoring the indicating controller of the specified station No.
After selecting, set the station No. of the indicating controller in the following range.
0 to 94:To monitor the indicating controller of the specified station No.
95:Same as the setting of [All].
100 to 115:To specify the station No. of the indicating controller to be monitored by the value of GOT data register (GD).
The device name is displayed as follows when the memory number (0 to 7) is set.
Memory No.
None
0
1
2
3
4
5
6
7
The following shows the relation between station numbers of the indicating controller and the GOT data register.
Station No.
100
101
:
114
115
Description
Device Number
M0/Device Number
M1/Device Number
M2/Device Number
M3/Device Number
M4/Device Number
M5/Device Number
M6/Device Number
M7/Device Number
GOT data register (GD)
GD10
GD11
:
GD24
GD25
Displayed device name
Setting range
0 to 94
(If setting a value outside the range above, a
device range error occurs.)
*2