05.08
Which SGEs/SGAs are required for the test stop of external STOPs?
The following SGEs/SGAs can be used to perform the test stop for external
STOPs:
Table 6-9
NCK moni-
toring chan-
nel
Drive moni-
toring chan-
nel
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Safety Functions Integrated in the System/Drive
SGEs/SGAs for the test stop, external STOPs
NCK–SGE "deselect ext. STOP A"
NCK–SGA "STOP A/B is active"
NCK–SGE "deselect ext. STOP C"
NCK–SGA "STOP C is active"
NCK–SGE "deselect ext. STOP D"
NCK–SGA "STOP D is active"
NCK–SGE "deselect ext. STOP E"
NCK–SGA "STOP E is active"
PLC–SGE "deselect ext. STOP A"
PLC–SGA "STOP A/B is active"
PLC–SGE "deselect ext. STOP C"
PLC–SGA "STOP C is active"
PLC–SGE "deselect ext. STOP D"
PLC–SGA "STOP D is active"
PLC–SGE "deselect ext. STOP E"
PLC–SGA "STOP E is active"