Siemens SINUMERIK 840D sl Function Manual page 329

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
Unit:
Default value:
[0] 100
[1] 101
[2] 102
[3] 103
[4] 104
[5] 105
[6] 106
[7] 107
[8] 108
[9] 109
[10] 110
[11] 111
[12] 112
[13] 113
[14] 114
[15] 200
[16] 201
[17] 202
[18] 203
[19] 204
[20] 205
[21] 206
[22] 207
[23] 208
[24] 209
[25] 210
[26] 211
[27] 212
[28] 213
[29] 214
p9540
SI motion SCA (SN) tolerance (Control Unit)
Sets the tolerance for the "Safe Cam" function (SCA).
Within this tolerance, both monitoring channels may signal different signal
states of the same safe cam.
Unit:
Default value:
mm, degrees
0.1
p9542
SI motion actual value comparison tolerance (crosswise) (Control Unit)
Sets the tolerance in mm or Degrees for the crosswise comparison of the
actual position between the two monitoring channels
Unit:
Default value:
mm
0.1
See also: C01711 "SI motion: Defect in a monitoring channel".
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Minimum value:
Maximum value:
100
414
Minimum value:
Maximum value:
0.001
10 mm or
10 degrees
Minimum value:
Maximum value:
0.001
10 mm or 360 de-
grees
Data Description
8.2 Parameters for SINAMICS S120
Data type:
U32
Checksum:
Yes
Data type:
Floating point
Checksum:
Yes
Data type:
Floating point
Effective:
POWER ON
Protection level:
4
Effective:
POWER ON
Protection level:
3
Effective:
POWER ON
8-329