Siemens SINUMERIK 840D sl Function Manual page 565

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

05.08
N30620 (F, A)
Response
Acknowledgement
Explanation
Remedy
Response as for F
Acknowledgement for F IMMEDIATELY (POWER ON)
Response
Acknowledgement for A NONE
N30621 (F, A)
Response
Acknowledgement
Explanation
Remedy
Response as for F
Acknowledgement for F IMMEDIATELY (POWER ON)
Response
Acknowledgement for A NONE
© Siemens AG 2008 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Re fault value = 2000, 2001, 2002:
– Check the tolerance time SGE changeover and if required, increase
the value (p9650, p9850).
– Check the wiring of the safety–related inputs (SGE) (contact problems).
– Replace the Motor Module involved.
SI MM: Safe torque off active
NONE
NONE
The "Safe torque off active" function was selected on the Motor Module
(MM) and is active.
Note:
This message does not result in a safety stop response.
None necessary.
OFF2
NONE
SI MM: Safe Stop 1 active
NONE
NONE
The "Safe Stop 1" (SS1) function has been selected on the Motor
Module (MM) and is active.
Note:
This message does not result in a safety stop response.
None necessary.
OFF2
NONE
10.3 Safety messages for SINAMICS S120