Diagnostics
10.3 Safety messages for SINAMICS S120
Remedy
F01611
Response
Acknowledgement
Explanation
10-542
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 05.2008 Edition
Select safe standstill and then deselect again.
– Replace the Motor Module involved.
Re fault value = 9999:
– Carry out diagnostics for fault F01611 that is present.
SI CU: Defect in a monitoring channel
NONE (OFF1, OFF2, OFF3)
IMMEDIATELY (POWER ON)
The "Safety Integrated" function integrated in the drive on the Control
Unit has detected a fault in the crosswise data comparison between CU
and Motor Module (MM) and has initiated a STOP F.
As a result of this fault, after the parameterized transition has expired
(p9658), fault F01600 (SI CU: STOP A initiated) is output.
Fault value (r0949, decimal):
0:
Stop request from the Motor Module
1 to
Number of the crosswise compared data that resulted in this fault.
999:
This number is also displayed in r9795.
1: SI monitoring clock cycle (r9780, r9880).
2: SI enable safety functions (p9601, p9801).
3: SI SGE changeover, tolerance time (p9650, p9850).
4: SI transition time STOP F to STOP A (p9658, p9858).
5: SI enable safe brake control (p9602, p9802).
6: SI motion, enable safety functions (p9501, internal value).
7: SI delay time of the pulse cancellation for Safe Stop 1 (p9652,
p9852).
8: PROFIsafe address (p9610, p9810).
1000:
Check (watchdog) timer has expired. Within the time of approx.
5 * p9650 too many switching operations have occurred at terminal
EP of the Motor Module.
1001,
Initialization error, change timer/check timer.
1002:
2000:
Status of the SH terminals on the Control Unit and Motor Module are
different.
2001:
Feedback signal for safe pulse cancellation on the Control Unit and
Motor Module are different.
2002:
Status of the delay timer SS1 on the Control Unit and Motor Module
are different.
2004:
Status of the SH selection for modules connected in parallel are
different.
2005:
Feedback signal of the safe pulse cancellation on the Control Unit
and Motor Modules connected in parallel are different.