11.14

AT^SGCONF Configuration of GPRS related Parameters

Syntax
Test Command
AT^SGCONF=?
Response(s)
^SGCONF: (list of supported <llc_pdu_length_U>s), (list of supported
OK
Read Command
AT^SGCONF?
Response(s)
^SGCONF: <llc_pdu_length_U>,
OK
Write Command
AT^SGCONF=[<llc_pdu_length_U>][,
Response(s)
OK
ERROR
+CME ERROR
Reference(s)
SIEMENS
Parameter Description
<llc_pdu_length_U>
The maximum number of octets in an information field of Unnumbered (U) frames.
0
(P)
140...1520
(num)
<GPRS msclass>
GPRS Multislot Class. The value can be one of the classes indicated with the Test command. The value set is
volatile and powerup value is the maximum allowed.
Notes
+CME ERROR: invalid index: Parameter is out of range
+CME ERROR: operation temporary not allowed: The command is blocked as long as GPRS is already in
use (as long as mobile is GPRS attached).
Writing to user profile with
MC55_ATC_V04.00
Confidential / Released
<GPRS msclass>
[<GPRS
(num)
No negotiation with network (500 will be used).
Lower values diminish performance.
and restoring with
AT&W
Page 292 of 475
msclass>]]
PIN
ASC0 ASC1
MUX1
!
%
%
%
are not supported.
AT&F
<GPRS
msclass>es)
MUX2
MUX3 Charge
%
%
!