Siemens SINAMICS S120 Equipment Manual page 336

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Options
8.6 K46, SMC10 Sensor Module Cabinet-Mounted for resolvers
-X520 encoder interface
Table 8- 5
Encoder interface -X520
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Connector type: 25-pin sub D connector (pin)
336
Signal name
Reserved, do not use
Reserved, do not use
S2
S4
Ground
S1
S3
Ground
R1
Reserved, do not use
R2
Reserved, do not use
+ Temp
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Ground
- Temp
Technical specifications
Resolver signal A (sin+)
Inverted resolver signal A (sin-)
Ground (for internal shield)
Resolver signal B (cos+)
Inverted resolver signal B (cos-)
Ground (for internal shield)
Resolver excitation positive
Resolver excitation negative
Motor temperature measurement KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130/PTC
Ground (for internal shield)
Motor temperature measurement KTY84-1C130 (KTY-)
Temperature sensor KTY84-1C130/PTC
S120 Cabinet Modules Equipment Manual
Manual, (GH5), 10/2008, A5E00427098A