Electrical installation
4.2 Electrical installation: Checklist
Item
Activity
26
K50,
SMC30 Sensor Module
27
K76, auxiliary voltage
generating unit in the
Line Connection Module
28
K82, terminal module for
activating safety functions
"Safe Torque Off" and
"Safe Stop 1"
29
L25,
circuit breaker in
withdrawable unit design
30
L45,
EMERGENCY OFF
pushbutton in the cabinet
door
31
L46,
grounding switch
upstream of circuit
breaker
32
L47,
Grounding switch
downstream of circuit
breaker
48
The SMC30 Sensor Module is used for detecting the
actual motor speed.
The following encoders are supported by the SMC30
Sensor Module:
TTL encoder
HTL encoder
SSI encoder
(→ See the chapter titled "Options", section "K50, SMC30
Sensor Module for detecting the actual motor speed")
In order to supply the auxiliary voltage busbar system with
the appropriate voltages, the phase must be clamped to
the corresponding transformer tap.
Make sure that the correct voltage is applied.
(→ See the chapter titled "Options", section "K76, auxiliary
voltage generating unit in the Line Connection Module")
Connect according to "Cable routing for the "Safe Torque
Off" and "Safe STOP 1" functions".
(→ See the chapter titled "Options", section "Cable routing
for the "Safe Torque Off" and "Safe STOP 1" functions")
(→ See the chapter titled "Options", section "K82, terminal
module for activating safety functions "Safe Torque Off"
and "Safe STOP 1"")
Wire up the checkback contact.
(→ See the chapter titled "Options", section "L25, circuit
breaker in withdrawable unit design")
Include the option in the EMERGENCY OFF chain.
(→ See the chapter titled "Options", section "L45,
EMERGENCY OFF pushbutton in the cabinet door")
The interlock for the upstream, plant-side main breaker
must be ensured.
(→ See the chapter titled "Options", section "L46/L47,
grounding switch upstream/downstream of circuit breaker")
The main breaker cannot be closed when the grounding
switch is closed.
(→ See the chapter titled "Options", section "L46/L47,
grounding switch upstream/downstream of circuit breaker")
Applicable?/Completed?
S120 Cabinet Modules Equipment Manual
Manual, (GH5), 10/2008, A5E00427098A