Setting parameters for blocks
3.5 Programming the Ident profile
Table 3- 86
Address
0x0000
0x0001
0x0002
0x0003
0x0004
0x0005
0x0006
102
Command data area "TXREF" command identifier 0x08 (set Digital Out)
Value
0x08
0x01...0x04
0x00...0x02
0x01...0x07
0x00...0x05
0x00
0x00
Meaning
Command identifier "Set Digital Out"
Number of the logical external signal. Corre-
sponds to "EXT_1", "EXT_2", "EXT_3" and
"EXT_4".
Level of the signal
0x00: Set level statically to "low".
0x01: Set level statically to "high".
0x02: Set level for configured pulse time to
"high".
Type of logic operation
0x01: Logical "OR"
0x02: Logical "AND"
0x03: Logical "Exclusive OR"
0x04: no logic operation
0x05: Logical "OR not"
0x06: Logical "AND not"
0x07: Logical "Exclusive OR not"
Logical signal linked to.
If the logic operation type is 0x4, the parameter
has no significance.
0x00: Logical signal "IN_OP"
0x01: Logical signal "TRD"
0x02: Logical signal "RDY"
0x03: Logical signal "READ"
0x04: Logical signal "MATCH"
0x05: Logical signal "NOK"
Reserved, must be 0x00 to retain upwards com-
patibility.
Reserved, must be 0x00 to retain upwards com-
patibility.