Description of the parameters
Table 3- 3
Parameter
Input parameters
EN
EXECUTE
HW_CONNECT
Output parameters
DONE (BOOL)
ERROR (BOOL)
BUSY (BOOL)
STATUS (DWORD)
PRESENCE (BOOL)
ENO
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
Description of the input and output parameters
Description
Enabling Input
There must be a positive edge at this input before the block will exe-
cute the command.
Global parameter of the type "IID_HW_CONNECT" to address the
channel/reader and to synchronize the blocks. This parameter needs
to be created and addressed once for each channel/reader.
"HW_CONNECT" must always be transferred to the blocks to ad-
dress the relevant channel/reader.
The job was executed. If the result is positive, this parameter is set.
The job was ended with an error. The error code is indicated in Sta-
tus.
The job is being executed.
Display of the error message if the "ERROR" bit was set.
This bit indicates the presence of a transponder. The displayed value
is updated each time the block is called. This parameter does not
exist in blocks specific to optical reader systems.
Enable output
Setting parameters for blocks