Parameter
INVENTORY_DUR_UNIT
RXREF
Table 3- 61
Parameter
CMD
OFFSETBUFFER
LEN_DATA
EPCID_UID
LEN_ID
TXREF
Table 3- 62
Byte
Value
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
Value / description
Only for 0x80 and 0x81:
Unit for "DURATION"
0x00 ≙ time [ms]
0x01 ≙ inventories
0x02 ≙ number of transponders that achieve the "Observed" state
In the case of RF61xR/RF68xR, only with 0x80 and 0x81:
Data received
With RF620R/RF630R/RF300/MOBY U:
Data received
You will find the data structure of the status modes in the section
"Inventory (Page 31)".
FORMAT (not with RF200 and RF61xR/RF68xR)
Value / description
0x66
Offset in the "TXREF" send buffer
Length of the parameter data to be sent (15 bytes)
Buffer for up to 62 bytes EPC-ID, 8 bytes UID or 4 bytes handle ID.
2 - 62-byte EPC-ID is entered at the start of the buffer (length is
set by "LEN_ID")
8-byte UID is entered at the start of the buffer ("LEN_ID = 8")
4-byte handle ID must be entered in the array element [5]-[8]
("LEN_ID = 8")
Default value: 0x00 ≙ unspecified single tag access
Length of the EPC-ID/UID
Parameter data to be written
Structure of the data attachment for the "FORMAT" command with normal addressing
1...8
9
10
0x00
0x06
0x03
Setting parameters for blocks
3.5 Programming the Ident profile
11
12
13
0x00
INIT-Wert 0x00
14
15
MSB
LSB
85