Reset_Moby_U - Siemens Simatic Ident Function Manual

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

Setting parameters for blocks
3.4 Programming Ident blocks
3.4.3.2

Reset_MOBY_U

Figure 3-24
Table 3- 29
Parameter
TAG_CONTROL
DISTANCE
MULTITAG
SCAN_TIME
FCON
FTIM
52
"Reset_MOBY_U" block
Explanation of the "Reset_MOBY_U" block
Data type
Bool
Byte
Byte
Byte
Byte
Byte
Default values
Description
True
Presence check
23h
Range limitation
(range of values: 0x02 ... 0x23 or 0x82
... 0xA3 for reduced transmit power)
1
Maximum number of transponders
that can be processed at the same
time in the antenna field.
(Range of values: 0x01 ... 0x12)
0
Scanning time: Standby time of the
transponder
(range of values: 0x00 ... 0xC8)
0
field_ON_control: BERO mode
(range of values: 0x00 ... 0x03)
0
field_ON_time: Time for BERO mode
(range of values: 0x00 ... 0xFF)
Ident profile and Ident blocks, standard function for Ident systems