Write_Epc_Mem - Siemens Simatic Ident Function Manual

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

3.4.2.9

Write_EPC_Mem

The "Write_EPC_Mem" block overwrites the EPC memory of the RF600 transponder starting
at address 4. The length of the EPC memory to be overwritten is specified by the
"LEN_DATA" parameter.
Figure 3-21
Table 3- 26
Parameter
LEN_DATA
LEN_ID
EPCID_UID
IDENT_DATA
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
"Write_EPC_Mem" block
Explanation of the "Write_EPC_Mem" block
Data type
Word
Byte
Array[1...62] of
Byte
Any / Variant
Default values
Description
W#16#0
Length of the EPC memory to be
overwritten (1 ... 62 bytes)
B#16#0
Length of the EPC-ID/UID
Default value: 0x00 ≙ unspecified
single tag access (RF61xR, RF68xR)
0
Buffer for up to 62 bytes EPC-ID, 8
bytes UID or 4 bytes handle ID.
2 - 62-byte EPC-ID is entered at
the start of the buffer (length is set
by "LEN_ID")
8-byte UID is entered at the start
of the buffer ("LEN_ID = 8")
4-byte handle ID must be entered
in the array element [5]-[8]
("LEN_ID = 8")
Default value: 0x00 ≙ unspecified
single tag access (RF620R, RF630R)
0
Data buffer with the EPC memory data
to be overwritten.
Note:
For Variant, currently only an "Ar-
ray_of_Byte" with a variable length
can be created. For Any, other data
types/UDTs can also be created.
Setting parameters for blocks
3.4 Programming Ident blocks
49

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents