Siemens Simatic Ident Function Manual page 108

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

Setting parameters for blocks
3.5 Programming the Ident profile
Overview of the commands
Table 3- 90
Command
PHYSICAL-READ
PHYSICAL-WRITE
READER-STATUS
TAG-STATUS
INVENTORY
FORMAT
KILL-TAG
LOCK-TAG-BANK
Starting command repetition
You have the option of using command repetition with or without transfer of the command.
The various procedures are described below.
Sequence of the repeat command with simultaneous command transfer:
1. If applicable, enable presence mode (with RF61xR/RF68xR).
2. Start the command using the input parameter "EXECUTE" while "RPTCMD" is set at the
same time.
The command is processed and the result transferred to the Ident profile.
The Repeat command is activated on the reader.
3. The reader confirms activation with the output parameter "RPTACT" of the Ident profile.
The confirmation is made only after the first command has been executed.
The reader executes the command automatically as soon as a transponder is identified in
the antenna field.
If the reader does not support the Repeat command, "RPTACT" remains inactive. If
"EXECUTE" is nevertheless set, the error "0xE7FE0900" is output after a timeout of 10
seconds.
4. You can read out the individual results by repeatedly setting the "EXECUTE" input
parameter.
108
Overview of the commands with which command repetition is possible
Command code
HEX
ASCII
0x70
'p'
0x71
'q'
0x74
't'
0x73
's'
0x69
'i'
0x66
'f'
0x6A
'j'
0x79
'y'
Description
Reads data from a transponder / optical reader sys-
tem by specifying the physical start address, the
length and the password.
Writes data to a transponder / optical reader system
by specifying the physical start address, the length
and the password.
Reads out the status of the reader.
Reads out the status of a transponder.
Requests a list of all currently accessible transpond-
ers within the antenna range.
Initializes the transponder.
RF61xR/RF68xR:
The transponder is permanently deactivated.
RF61xR/RF68xR:
Defines a password for transponder access.
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04