Setting parameters for blocks
3.5 Programming the Ident profile
You will find more detailed information on the individual status modes in the manuals
matching the modes "FB 45", "FB55" and "SIMATIC RF620R/RF630R".
The identifiers of the status modes correspond to the following identifiers in the other
manuals:
0x04
0x82
0x83
0x84
0x85
3.5
Programming the Ident profile
3.5.1
Changing to Ident blocks / profile
The Ident blocks or the Ident profile replace "PIB_1200_UID_001KB" and its blocks. Apart
from the name changes, functional changes were also made to the block. Note the following
points if you want to upgrade an existing project with PIB blocks/"PIB_1200_UID_001KB"
from the library version V1.04 to the Ident blocks or the Ident profile from the library V2.0:
● Delete all previous blocks from the program.
● Adapt each point of use to the call for the new instruction.
● Change the data type of the following variables:
– "HW_CONNECT_VAR" → "IID_HW_CONNECT"
– "CMD_STRUCT" → "IID_CMD_STRUCT"
68
≙
0x01
≙
0x02
≙
0x03
≙
0x04
≙
0x05
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04