Error mes-
Description
sage
(hex)
0xE1FE0400
Only during initialization: Transponder is unable to execute the initialization command
Transponder is defective
0xE1FE0600
Error in transponder memory
The transponder has never been written to or has lost the contents of its memory due to battery failure.
Replace transponder (if battery bit is set)
Re-initialize transponder
0xE1FE0700
Password error
RF620R/RF630R: Incorrect password
0xE1FE0800
The transponder in the antenna field does not have the expected UID or has no UID.
0xE1FE0A00
The transponder is read/write-protected.
0xE1FE8100
The transponder is not responding.
0xE1FE8200
The transponder password is incorrect. Access is denied.
0xE1FE8300
The verification of the written transponder data has failed.
0xE1FE8400
General transponder error
0xE1FE8500
The transponder has too little power to execute the command.
Ident profile and Ident blocks, standard function for Ident systems