Error messages
4.3 Errors from the communications module/reader
Error mes-
Description
sage
(hex)
0xE2FE0100
Field disturbance on reader
•
Reader is receiving interference pulses from the environment.
–
External interference field. The interference field can be detected with the "inductive field indicator"
of the STG.
–
The distance between two readers is too short and does not correspond to the configuration guide-
lines
–
The connecting cable to the reader is disrupted, too long or does not comply with the specification
–
MOBY U: Transponder has left the antenna field during communication.
–
MOBY U: Communication between reader and transponder was aborted due to a disruption (e.g.
person/foreign body moving between reader and transponder).
Too many transmit errors
•
The transponder was unable to receive the command or the write data from the communications mod-
ule correctly even after several attempts.
–
The transponder is positioned exactly in the limit area of the transmission window
–
Data transmission to the transponder is being affected by external interference
CRC sending error
•
–
The transponder reports CRC error frequently (transponder is positioned in the limit area of the
reader; transponder and/or reader has a hardware defect)
Only during initialization: CRC error on receipt of acknowledgement from transponder (cause as for
•
field interference on the reader)
When formatting, the transponder must be in the transmission window of the reader, otherwise a
•
timeout error will occur, in other words:
–
The transponder is located exactly in the limit area of the transmission window
–
The transponder is consuming too much power (defective)
–
Bad "FORMAT" parameter setting for EEPROM transponder
RF600:
•
–
No ETSI channel free
–
Incorrect communication standard selected in the "INIT" command
–
Bad expert parameter
–
Power check of the ETSI wireless profile is incorrect
0xE2FE0200
More transponders are located in the transmission window than can be processed at the same time by
•
the reader.
There is more than one transponder in the transmission window.
•
RF620R/RF630R: Transponder power supply close to limit.
•
Increase the antenna power or reduce the distance to the transponder.
0xE2FE8100
There is no transponder with the required EPC-ID in the transmission window or there is no transponder at
all in the antenna field.
0xE2FE8200
The requested data is not available.
0xE2FE8300
The transponder signals a CRC error.
0xE2FE8400
The selected antenna is not enabled.
0xE2FE8500
The selected frequency is not enabled.
124
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04