Setting parameters for blocks
3.5 Programming the Ident profile
Byte
Value
98
RFID system Meaning
Note that individual settings or transponder families can be combined (e.g. ISO
15693 general + RF300). In this case, the relevant hex values need to be com-
bined (ISO 15693 general [0x01] + RF300 [0x10] = 0x11).
Note:
ISO 15693: The following ISO special functions are not supported:
AFI (Application Family Identifier)
DSFID (Data Storage Format Identifier)
Chip-specific added functions such as EAS, Kill commands, etc.
ISO 15693: With "TAG_TYPE(ftim) = 0x01", the readers of the 1st generation
support the ISO commands "Inventory", "ReadSingleBlock", "WriteSingle-
Block", "LockBlock," "GetSystemInformation" and for multitags also "Select"
and "ResetToReady".
If a previously unknown transponder cannot be identified based on the parame-
ters above, an error message is generated (error_MOBY= "0x0D").
Invalid parameters are rejected with an error message ("error_MOBY= 0x15").
Applies only to readers of the 2nd generation.
1)
RF600
ETSI/India variant: 0x00 ... 0x0F
Changing the channel assignment in
the ETSI wireless profile ("scan-
ning_time = 0x02"):
0x00: Default; the channels of the reader are used in four channel mode.
Note: The setting "0x0F" is identical to "0x00".
With bits 0 to 3 of the "field_ON_time" byte, a channel (frequency) plan can be
created for the situation in which several readers are operated in close proximity.
Readers that use different channels will interfere with each other to a lesser extent.
If only one channel is used per reader, the reader must pause for 100 ms at inter-
vals of 4 seconds (as of ETSI EN 302 208 V1.2.1). With time-critical applications, a
smaller loss in performance can therefore be assumed in contrast to 2 to 4-
channel mode of a reader.
If 2 to 4 channels per reader are used, the reader switches to another channel
after 0.1 seconds in two-antenna mode and after 4 seconds in single-antenna
mode. If only one of the 4 channels is selected, a pause of 100 ms is forced after 4
seconds according to the standard.
FCC and CMIIT variant: Normal: 0x00
MOBY U
Time for BERO mode (field_ON_control = 02)
Value
Description
0x00
Time monitoring is deactivated. The 2nd BERO is needed in order to
switch the field off.
0x01 ...
1 ... 255 s turn on time for the reader antenna field
0xFF
Changing the channel assignment in the
India wireless profile ("scanning_time =
0xC0"):