Siemens Simatic Ident Function Manual page 129

Rfid systems ident profile and ident blocks, standard function for ident systems
Hide thumbs Also See for Simatic Ident:
Table of Contents

Advertisement

Error mes-
Description
sage
(hex)
0xE6FE8A00
Enabling write protection on the transponder has failed.
0xE6FE8B00
The "Kill" command failed.
0xE7FE0100
In this state, only the "Reset_Reader" command ("WRITE-CONFIG" with "CMDSEL =1" and "CMD =
0x78") is permitted.
0xE7FE0200
The command code "CMD" or the value in "CMDSEL" is not permitted.
Possible cause / action to be taken:
The "CMDSEL" or "CMDDIM" parameter was set incorrectly. Check the parameters.
The value of the parameter "CMDSEL" must be between 1 and 100 and may never be higher than the
value of the "CMDDIM" parameter (max. 100).
0xE7FE0300
The value of the "LEN_DATA" parameter of the command is too long.
It does not match the global data reserved in the send data buffer (TXBUF).
0xE7FE0400
The receive data buffer (RXBUF) or the send data buffer (TXBUF) is too small, the buffer created at
TXBUF/RXBUF does not have the correct data type or the parameter "LEN_DATA" has a negative value.
Possible cause / action to be taken:
Check whether the buffers TXBUF/RXBUF are at least as large as specified in "LEN_DATA".
With S7-1200/1500:
In the Ident profile, only an "Array of Byte" may be created for TXBUF and RXBUF.
In the "Tag_Status" and "Reader_Status" blocks, only an "Array of Byte" or the corresponding data
types ("IID_TAG_STATUS_XX_XXX" or "IID_READER_STATUS_XX_XXX") may be created. With
all other blocks, only an "Array of Byte" may be created.
0xE7FE0500
This error tells you that only an "INIT" command is permitted as the next command. All other commands
are rejected.
0xE7FE0600
Wrong index (outside range of "101 ... 108" and "-20401 ... -20418")
0xE7FE0700
The reader or communications module does not respond to "INIT" ("INIT_ACTIVE" is expected in the cy-
clic status message).
The next steps:
Check the address parameter "LADDR".
0xE7FE0800
Timeout during "INIT"
(60 seconds according to "TC3WG9")
0xE7FE0900
Command repetition is not supported.
0xE7FE0A00
Error during the transfer of the PDU (Protocol Data Unit).
0xE7FE0B00
The "CMDREF" parameter was set incorrectly. Check the parameter.
The parameter "CMDREF" must be created as "ARRAY of IID_CMD_STRUCT" and may contain a max. of
100 elements.
0xFxFExx00
An "FxFExxxx" error is identical to the corresponding "ExFExxxx" error (see "ExFExxxx" error).
Byte 3 contains additional warning information.
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04
4.3 Errors from the communications module/reader
Error messages
129