Connectors; Table 4-28 Gcd-4Diopb Rj-61 Cable Connector Pin-Outs - NEC Univerge SV9100 System Hardware Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
Table 4-27 GCD-4DIOPB LED Indications (Continued)
LED Indication
Live LED
Busy LED (Red)
(Green)
On
Off
Off
Flash 80ms (On/
Off) x 3/400ms
Off
SV9100 System Hardware Manual
Operation Status
A Channel is busy (use
Unit Busy
another from CH1 ~ CHx).
All channels are idle.
Downloading firmware.
5.5.4

Connectors

The CN2 connector provides connection to four analog DID trunk ports,
which are polarity sensitive (tip-to-tip, ring-to-ring). The OPX circuits,
however, are not polarity sensitive. The GCD-4DIOPB requires one
universal slot. (Refer to
Program 10-03-01 has OPX defined, note that the blade consumes four
(4DIOPA) trunks and extension ports when installed. If OPX is not defined,
then only trunks ports are consumed.

Table 4-28 GCD-4DIOPB RJ-61 Cable Connector Pin-Outs

pin-outs for the RJ-61 connector.
4-65
shows the location of the connectors on the 4DIOPA blade.
Table 4-28 GCD-4DIOPB RJ-61 Cable Connector Pin-Outs
Figure 4-23 GCD-4DIOPB Blade on page
Figure 4-23 GCD-4DIOPB Blade on page
RJ-61 Cable Connector – CN2
Line No.
Pin No.
1
5
4
2
3
6
3
2
7
4
1
8
Remarks
4-65.) If
shows the
Connection
Tip
Ring
Tip
Ring
Tip
Ring
Tip
Ring
4-67