Figure 7-34 Install Apr-L Unit - NEC Univerge SV9100 System Hardware Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 2.0
SV9100 System Hardware Manual

Figure 7-34 Install APR-L UNIT

8.
Return tilt leg to original position.
9.
For the APR adapter to be recognized correctly, before plugging in
the multiline terminal, make sure the extension number to be used for
the adapter is undefined in Program 10-03-01.
10.
Plug the line cord back into the multiline terminal.
To avoid any hardware problems, unplug the line cord,
then any other adapter cables, BEFORE REMOVING
WARNING
THE ADAPTER.
11.
To determine the APR analog extension number
10-03-04 : Optional Installed Unit 1
Display the type of terminal installed. This can be used to verify that
the system recognizes the adapter.
10-03-06 : Terminal Type (B2)
Assign the terminal type (12) for the telephone channel, which has
the APR Adapter installed.
When you want the APR to use the same extension number as the
telephone to which it is attached, remove the terminal type in this
option. With this setup, when the analog device is in use, it busies out
the terminal as there is no separate port number assigned for the
adapter. To reverse this, and allow the APR to have its own extension
number, reassign the terminal type (12) in this option.
10-03-07 : Logical Port Number (B2) Read Only
The port number of the APR Adapter is displayed for the extension
(APR ports = 193~512 with all software through 3.07). The ports are
assigned from the highest available port down.
7-39