What to do?
5.2
Configuring the
motor data
Caution
If the motor is replaced after transferring project data from the programming device to the drive, then before any data is
transferred again, the pulse frequency must be checked.
5.3
Configuring a
motor brake
5.4
Configuring an
encoder
5.5
Entering encoder
data
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
2.7 First commissioning, vector control mode in the chassis format
1. If your motor is not in the default list, select Enter motor data
and jump to point 5.2.
2. Click on your motor type in the "Motor type" list.
3. Click on "Continue >".
1. Enter your motor data according to the data sheet.
1. Alternatively, after entering the motor data, carry out a motor
identification when commissioning for the first time.
Alternatively, you can use motor data from the template.
1. Follow the wizard by clicking on "Next >".
2. If known, you can enter the mechanical data of the motor and
the drive train or the data of a PE spindle.
3. If necessary, select a complete calculation of the
motor/controller data without equivalent circuit diagram data.
4. For this example, select the simple drive.
1. If you are not using a motor holding brake, click on "Continue
>".
2. If you are using a motor holding brake, you can select and
configure the brake in this window.
3. Click on "Continue >".
You can connect up to 3 encoders.
1. If you are using a DRIVE-CLiQ encoder, then select the
appropriate item.
2. Click on "Next >".
The encoder is automatically identified and configured.
1. Alternatively, you can use a standard encoder.
Select the encoder from the list.
2. Click on "Continue >".
Alternatively, you can use your own encoder.
1. Select enter data.
2. Click on encoder data.
3. Select the measuring system.
4. Enter the required data and click on "OK".
5. Click on "Continue >".
1. Enter the encoder data into the input screen form.
2. Click on "OK".
How to do it?
Commissioning
Comment
If you have no mechanical
data to enter, then the data
are estimated based on the
rating plate data. The
equivalent circuit diagram
data is also estimated on
the basis of the data on the
rating plate or determined
by means of automatic
motor data identification.
For more information, see
the Function Manual.
If you are using an encoder
that is not in the list, you
can also manually enter the
data.
By clicking on details, you
can view the data of the
encoder selected from the
encoder list.
Enter additional encoders
in the same way as
described above
123

Advertisement

Table of Contents
loading