Siemens SINAMICS S120 Commissioning Manual page 224

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnostics
3.2 Diagnostics via STARTER
Start function generator:
1. Load the function generator.
2. Select "Function generator as a commissioning tool".
3. Select an operating mode e.g. "Speed setpoint after filter".
4. Select a drive, for instance "SERVO_02".
5. Set a signal shape, for example, "Squarewave".
6. Click the "Assume control priority!" button.
7. For "Sign of life monitoring" click on the "Accept" button.
8. Click on the symbol
9. Start the function generator by clicking on the triangle next to the red zero ( "Start
10. Carefully read the "Caution" note and confirm with "Yes".
Stopping the function generator:
1. Click on the "Stop FctGen" button.
2. Click on the symbol
Parameterization
The "function generator" parameter screen is selected using the following icon in the toolbar
of the STARTER commissioning tool:
Figure 3-4
222
– Click on the symbol
or
– In the project navigator, double-click on "Drives" > "Drive_xy" > "Commissioning" >
"Function generator".
(the control priority button then changes to yellow).
FctGen" button).
The drive starts and executes the selected trace function.
Trace recordings are now possible.
Or
STARTER icon for "Device trace-function generator"
"Drive on".
"Drive off" in order to stop the drive.
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2