Siemens SINAMICS S120 Commissioning Manual page 54

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Preparation for commissioning
1.6 Powering-up/powering-down the drive system
Control and status messages
Table 1- 15
Power-on/power-off control
Signal name
0 = OFF1
0 = OFF2
0 = OFF3
Enable operation
Table 1- 16
Switch-in/switch-out status signal
Signal name
Ready for switching on
Ready for operation
Operation enabled
Pulse inhibit
Pulses enabled
only available in Interface Mode p2038 = 0
1)
Function diagrams (see SINAMICS S120/S150 List Manual)
● 2610 Sequence control - sequencer
● 2634 Missing enable signals, line contactor control
● 8732 Basic Infeed - sequencer
● 8832 Smart Infeed - sequencer
● 8932 Active Infeed - sequencer
52
Internal control word
STWA.00
STWAE.00
STWA.01
STWAE.01
STWA.02
STWA.03
STWAE.03
Internal status word
ZSWA.00
ZSWAE.00
ZSWA.01
ZSWAE.01
ZSWA.02
ZSWAE.02
ZSWA.06
ZSWAE.06
ZSWA.11
Binector input
p0840 ON/OFF1
p0844 1. OFF2
p0845 2. OFF2
p0848 1. OFF3
p0849 2. OFF3
p0852 Enable operation
Parameter
r0899.0
r0899.1
r0899.2
r0899.6
r0899.11
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
PROFIdrive/Siemens
telegram 1 ... 352
STW1.0
STW1.1
STW1.2
STW1.3
PROFIdrive/Siemens
telegram 1 ... 352
ZSW1.0
ZSW1.1
ZSW1.2
ZSW1.6
ZSW2.10
1)
Commissioning Manual

Advertisement

Table of Contents
loading

Table of Contents