6.3.2 STANDARD I/O connector optional cable for USA Specification
The STANDARD I/O cable is an optional part and for USA specification.
Pin No.
RC420 Rev.9
Setup & Operation
- Pin Assignments
Signal Name
1
Input common No. 0 to 7
2
Input No. 0
3
Input No. 1
4
Input No. 2
5
Input No. 3
6
Input No. 4
7
Input No. 5
8
Input No. 6
9
Input No. 7
10
Input common No. 8 to 15
11
Input No. 8
12
Input No. 9
13
Input No. 10
14
Input No. 11
15
Input No. 12
16
Input No. 13
17
Input No. 14
18
Input No. 15
19
Output No. 0
20
Output No. 1
21
Output No. 2
22
Output No. 3
23
Output No. 4
24
Output No. 5
25
Output No. 6
6.3 Pin Assignments (D-I/O Connector)
Pin No.
Signal Name
26
Output No. 7
27
NC
28
Output No. 8
29
Output No. 9
30
NC
31
Output No.10
32
Output No.11
33
NC
34
Output No.12
35
NC
36
Output No.13
37
NC
38
Output No. 14
39
NC
40
NC
41
Output No. 15
42
NC
43
NC
44
Output common
45
Output common
46
Output common
47
+24V Output
48
+24V Output
49
+24V GND Output
50
+24V GND Output
47

Hide quick links: