Input Circuit - Epson RC420 Manual

Robot controller
Table of Contents

Advertisement

Setup & Operation 7.2 Protected Expansion I/O Board (Expansion I/O Board - Optional)
7.2.2 Protected Expansion I/O Board : Input Circuit
The following diagrams illustrate cases where #48 through #79 (for the first Expansion
I/O Board) are assigned to the Protected Expansion I/O Board's (or Expansion I/O
Board's) inputs and outputs. The I/O number assignment depends on the controller
software settings.
Input Voltage Range
ON Voltage
OFF Voltage
Input Current
■ Use the PNP-type of wiring diagram for CE conformance. Be sure to wire
correctly.
Manipulator move unusually.
CAUTION
Protected Expansion I/O Board
Typical Input Circuit Application 1: NPN
RC420 Rev.9
: + 12 V to 24 V ±10%
: + 10.8 V (Min.)
: + 5 V (Max.)
: 10 mA (TYP) at + 24 V input
Improper wiring may cause safety problems as it may make the
470 Ω
2.2 kΩ
(Same)
(Same)
(Same)
(Same)
(Same)
~
(Omit)
1 Input No.48 to 51 common
3 Input No.48
4 Input No.49
5 Input No.50
6 Input No.51
51 Input No.52 to 55 common
53 Input No.52
54 Input No.53
~
~
GND +DC
51

Hide quick links:

Advertisement

Table of Contents
loading