10. Connect board transfer signal lines and check their connection
Connect the board transfer signal lines from the upstream and downstream machines to YSP10.
10.1. Connect board transfer signal lines to YSP10
Remove the upper and lower covers of the machine rear side, relevant connectors can be accessed.
Connect the signal line from the previous machine to the connector labeled "PREVIOUS", the line from
the next machine to the connector labeled "NEXT", then arrange the harnesses using cable ties or so.
Connect a cable with the
"PREVIOUS" mark tube.
INTERFACE connector
SI1906002E-001=YSP10 installation and adjustment procedures
46/120
For Service Engineers
Service Information
Connect a cable with the
"NEXT" mark tube.
Lower cover
of rear side